Fluorocarbon Hose Limited manufactures a wide range of hoses for hydrogen/water-cooled turbine generators. The stator winding circuits are directly cooled by de-ionised water which is supplied from a distribution header via flexible PTFE hoses.
Generator hose assemblies typically comprise unbraided thick-wall PTFE tubing with stainless steel or phosphor bronze fittings swaged on each end. The PTFE hose is formed into specific shapes to fit the generator.
Our Service
Smooth bore PTFE tubing, providing low resistance to flow
Available in virgin and black pigmented PTFE
Minimum design life of 25 years
PTFE processed for maximum flex life
Bespoke hoses manufactured to customer specification
Standard and custom fittings available in non-magnetic stainless steel and phosphor bronze
Hoses permanently formed into specific shapes to suit the generator profile
Available in lengths up to 6m
Resistivity: >10₁₇ Ohm (10 to the power 17) (virgin PTFE)
Quality
Fluorocarbon operate a Quality Management System to ISO9000:2008 and offer the following:
In process material testing
Internal & external pressure testing
Vacuum testing
Vibration testing
100% final product inspection
Full QA documentation and traceability
Standard Hose Sizes
Hose Ref.
ID
OD
Wall
mm
mm
mm
M900-25S
6.3
9.7
1.7
M900-308E
8
11.1
1.6
M900-10/14
10
14
2
M900-50D
12.7
15.9
1.6
M900-50E
13.2
20.1
3.4
M900-50B
12.7
17.5
2.4
M900-15/20
15
20
2.5
M900-625S
16
22
3
M900-75E
19.4
25.4
3
M900-75S
18.8
26.4
3.8
M900-100S
25
35
5
M900-25/37
25
37
6
Non-standard sizes available on request
Fittings
Standard and custom fittings are available in the following materials:
Stainless steel 316L (X2 Cr Ni Mo 17-12-2) or 1.4404 as per EN10088-3
Stainless steel F321 (X6 Cr Ni Ti 18-10) or 1.4541 as per EN10088-3
Stainless steel 316 (X6 Cr Ni Mo Ti 17-12-2) or 1.4571 as per EN10088-3
Phosphor bronze to BS – EN 12163:1998 (CW451K-R390)
Other materials available on request.
Contact Us
Fluorocarbon Caxton Hill
Hertford
Herts
SG12 7HT
UK